Projects List
-
Queens College, Flushing NY
In Process of installing an 300kVA Diesel Generator with Rigging, Erection, Commissioning, testing and training and to provide with new underground Electrical Feeders and Automatic Transfer Switches.
-
Queensboro Community College, Bayside, NY
Installed 125kVA Diesel Generator. Provided Rigging, Erection, and Commissioning, testing and training with new Electrical Feeders.
-
Queensboro Community College, Bayside, NY
Installed 75Kva Step down Transformer @5KV rating. Provided Rigging, Erection, and Commissioning, testing and training with new Electrical Feeders. Extension of the primary cable and splices.
-
Bronx Family Court House, Bronx, NY
Charan Electric was responsible for complete line set up of High Voltage and Low Voltage tasks, including but not limited to New Electrical Switch gears, Power distribution with Automated Controls, Fire Alarm, and Interior lightings to newly renovated Building of more than 10,000 sq. ft.
-
Harlem Hospital, Bronx, NY
Charan Electric was responsible for complete setup of electrical requirements for newly built X-ray Laboratory, including but not limited to new 45kva step up transformer, feeders, Distribution panels, TVSS Receptacles and switches, new lighting fixtures and wiring for new installed X-ray machines, etc.
-
New York City Housing Authority
James Weldon Johnson Houses, Manhattan NY Completed date: March 31st 2011 Charan Electric was responsible for complete line set up of High Voltage and Low Voltage tasks, including but not limited to New Electrical Switch gear 4000A, Power distribution, PA System, Security Surveillance Systems, Fire Alarm, Interior and exterior lightings to new Buildings of more than 30,000 sq ft.
-
NYS Office Of General Services-
Completed date: March 22nd 2010
-
Ella McQueen Residential Center, Brooklyn, NY
Charan Electric was responsible for complete line set up of High Voltage and Low Voltage tasks, including but not limited to new Power distribution, Lightings, Fire Alarm Systems to newly renovated Buildings of more than 20,000 sq ft.
-
NYC - Department Of Design And Construction Museum Of Harlem, Manhattan NY
Completed date: July 30th 2009 Charan Electric was responsible for complete line set up of High Voltage and Low Voltage tasks, including but not limited to New Electrical Switch gears, Power distribution, PA System, Security Surveillance Systems, Fire Alarm, Interior and exterior lightings to newly renovated Building of more than 10,000 sq ft.
-
NYC Department Of Parks And Recreation
Roy Wilkins Park and Recreation Center, Jamaica, NY Completed date: December 5th, 2008 Installed 125kVA Diesel Generator. Provided Rigging, Erection, Commissioning, testing and training and responsible for the complete line set up of High Voltage and Low Voltage tasks, including but not limited to New Electrical Switch gears, Power distribution, Security Surveillance Systems, Fire Alarm, Interior and exterior lightings to new Building of more than 10,000 sq ft.
-
New York City Housing Authority
Charan Electrical enterprise got project from NYCHA to install different types of high end CCTV cameras and video surveillance system for their more than 16 different sites in Queens, Bronx and Manhattan. Many NYCHA sites contained up to 15 buildings. All work of this project from scoping to project hand over is done Charan Electrical enterprise in very limited time. The following work is done by Charan Electrical enterprise to accomplish all NYCHA projects.
• Our highly trained, experienced technicians performed conduit in complex and challenging buildings of NYCHA with high quality of work.
• All wiring including electrical and data cables (Optical Fiber and Cat 6) related to the CCTV done by our qualified electricians.
• Charan Electrical enterprise performed optical fiber and network cable (CAT 6) testing with industries high end equipment. All data cables passed with very well margin.
• LVC/Box • Servers • Network equipment